比浊法测定土壤有效硫的优化及与ICP-OES 法对比
作者:
作者单位:

(1.中国热带农业科学院农产品加工研究所/ 农业农村部农产品加工质量安全风险评估实验室(湛江),广东 湛江 524001;2.农业农村部环境保护科研监测所/ 农田有机污染生物消减创新团队/ 农业农村部产地环境污染防控重点实验室/ 天津市农业环境与农产品安全重点实验室,天津 300191;3.中国农业科学院农业环境与可持续发展研究所/ 农业农村部农业环境重点实验室,北京 100081;4.天津市农业科学院农产品质量安全与营养研究所,天津 300381)

作者简介:

潘政(1995-),研究实习员,硕士研究生,主要从事产地环境污染监测与修复研究。E-mail:panzheng361@163.com。

通讯作者:

基金项目:

基金项目:海南省自然科学基金(321QN0927,323QN289);中央级公益性科研院所基本科研业务费专项(1630082022006)。


Optimization of turbidimetric method for detecting soil available sulfur and comparison with ICP-OES method
Author:
Affiliation:

(1.Agricultural Products Processing ResearchInstitute,Chinese Academy ofTropical AgriculturalSciences,Zhanjiang Guangdong524001;2.Agro -Environmental ProtectionInstitute,Ministry of Agriculture and Rural Affairs/Key Laboratory of Original Agro-Environmental Pollution Prevention andControl,Ministry of Agriculture and Rural Affairs/Tianjin Key Laboratory of Agro-Environment and Agro-ProductSafety,Tianjin300191;3.Institute of Agricultural Environmentand Sustainable Development,Chinese Academy of Agricultural Sciences/Key Laboratory forAgriculturalEnvironment,Ministry of Agriculture and RuralAffairs,Beijing100081;4.Institute of Agricultural ProductQuality,Safety andNutrition,Tianjin Academy of AgriculturalSciences,Tianjin300381)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
    摘要:

    第三次全国土壤普查意义重大,为确保普查数据真实可靠,需对行业标准检测方法进行反复验证以优选出适合在全国范围内推广的方法。由于NY/T 1121.14—2006 比浊法测定土壤有效硫标准曲线线性较差,亟须优化其提取、测定条件以提高方法的准确度和精密度。鉴于此,主要探究了沉淀剂的状态、品牌及线性拟合方式对比浊法测定土壤有效硫标准曲线线性的影响,结果表明,有效硫标准曲线改用现用现配的40 g/L 氯化钡溶液定容可显著提高标准曲线的线性,使其相关系数r>0.999,满足分析测试的要求。同时本实验室对电感耦合等离子体光谱法(ICP-OES)测定土壤有效硫进行方法验证、对比,比浊法、ICP-OES 法的检出限分别为1.20、0.80 mg/kg,均满足分析测试的要求。方法准确度和精密度验证结果表明,二者均可用于土壤有效硫的测定并且测定结果无显著性差异。其中,比浊法适用于测定低含量(<48 mg/kg)样品,ICP-OES 法适用于含量范围在0 ~ 150 mg/kg 的样品。结合本实验室在第三次全国土壤普查内业检测试点工作中的经验,建议将ICP-OES 法作为第三次全国土壤普查有效硫测定的首选方法,以期为第三次全国土壤普查内业检测提供参考和借鉴。

    Abstract:

    The 3rd National Soil Survey is of great significance. In order to ensurethe authenticity and reliability of thedata, the standard detection methods need to be repeatedly verified to optimize the method suitable for nationwide promotion. Due to poor linearity of the standard curve of turbidimetric method in NY/T 1121.14—2006 todetect soil availablesulfur,it is urgent to optimize the extraction and determination conditions to improve the accuracy and precision of the method. In viewofthis,it was explored the influence of the state and brand of precipitator and the method of linear fitting on the linearity of the standard curveof the turbidity method in the paper. The result showed that the correlationcoefficient( r)of the standard curve can be >0.999 and meet the requirements of analysis if the freshly prepared 40 g/L BaCl2 is used. At the sametime,the determination of soil available sulfur by inductively coupled plasmaspectroscopy(ICP -OES)was verified and compared. The detection limits of turbidimetric method and ICP-OES were 1.20 and 0.80mg/kg,respectively,which satisfied the requirements of analysis and test. The results of accuracy and precision verification showed that turbidimetric method and ICP-OES could be used for the detection of soil available sulfur and there was no significant difference in the results. The turbidimetric method was suitable for the determination the samples with concentration below48 mg/kg,and the ICP-OES was better to the samples ranging of 0-150 mg/kg samples. Based on the experience in detection of 3rd National Soil Survey pilotwork,it was suggested that ICP-OES should be as the standard method for the determination of soil availablesulfur, which could provide reference for the 3rd National Soil Survey.

    参考文献
    相似文献
    引证文献
引用本文

潘政,赵丽霞,陕红,占国艳,潘晓威,梁耀辉,刘丽丽,欧阳小雪,孙宝利,叶剑芝.比浊法测定土壤有效硫的优化及与ICP-OES 法对比[J].中国土壤与肥料,2024,(1):238-246.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
历史
  • 收稿日期:2023-01-11
  • 最后修改日期:
  • 录用日期:2023-04-07
  • 在线发布日期: 2024-04-09
《中国土壤与肥料》招聘启事
关闭